RICOM Briefly Describes The Four Types Of Fluorine Deficiency in Industrial Chillers

Apr 19, 2023 Leave a message

1. Compressor load becomes larger

There are many reasons for the increase in compressor load, but if the industrial chiller lacks fluorine, the compressor load will inevitably increase. If the air-cooled and water-cooled systems do not have poor heat dissipation, the reason for the increased compressor load is often the lack of fluorine.

2. Decreased cooling capacity and decreased cooling efficiency

There may be many reasons for the decline in the cooling capacity of industrial chillers, but when the chiller lacks fluorine, especially when there is a large amount of fluorine deficiency, the cooling capacity of the chiller will definitely drop significantly, which will definitely affect the production efficiency of the enterprise.

3. High exhaust temperature

High exhaust temperature is a common phenomenon in industrial chillers. The pressure and thermometer at the exhaust end can clearly read the exhaust temperature. High exhaust temperature is not a rare phenomenon. Many people face the problem of high exhaust temperature of chillers. Respond negatively. In fact, the high exhaust temperature is due to the abnormal operation of the oil separator and insufficient refrigeration lubricating oil.

4. Large energy consumption and large wear of the compressor

Insufficient refrigerant, industrial chillers cannot meet the cooling demand, the chilled water outlet temperature does not meet the standard, the compressor will increase the load to meet the chilled water outlet demand, the power resource consumption is large, and the compressor wears heavily.

That is to say, in many cases, it is not easy to observe the lack of fluorine, especially for large-scale industrial chillers, if the refrigeration capacity and refrigeration efficiency drop slightly, it is difficult to find it immediately. It is recommended that the staff of the chiller manufacturer Can be detected with electronic detectors. The probability of insufficient fluorine is high because there are problems with refrigerant management and refrigerant flow pipes such as condensers, valves, etc. In the case of insufficient fluorine, it is necessary to detect leaks, determine the location of the leak, and then capture it , confirm that the refrigerant does not leak, and after the capture is successful, start the refrigerator.

 

Nanjing RICOM Refrigeration Equipment Co., Ltd. is a manufacturer specializing in industrial temperature control technology for 20 years. It implements the modern quality management system S09001: 2008 and environmental system IS014001: 2004 standards to ensure that the enterprise team continues to innovate in the technical field. Focusing on customer use and satisfaction, it has been unanimously recognized by the industry and customers; it has obtained AAA credit rating certification; in 2016, it was a contract-abiding and trustworthy enterprise. Warm machine production base, and established Chuzhou RICOM Plastic Technology Co., Ltd.