Industrial water chiller is the necessary equipment in industrial production, and each unit in operation, can not do without the participation of refrigerant, so the lack of refrigeration capacity will affect the normal operation of the machine. If there is a problem, it will bring a lot of trouble to use. The cooling capacity of the chiller is insufficient, or the cooling is very slow. When we encounter these problems, how to solve them?
Reasons for insufficient cooling capacity or slow cooling of chiller:
The occurrence of this situation is related to the large loss of cooling capacity. Because the insulation thickness of equipment and pipeline is not enough or the insulation layer is damaged, the cooling loss increases and the cooling effect is affected. In operation, once the outer surface of the insulation layer is wet or frosted, it means that the thickness of the insulation material is not enough or it has been affected by moisture. At this time, the insulation material should be added or replaced in time. In addition, the evaporator water tank cover is not tight, the seal of the air handling room or cold storage door is damaged, and the air-conditioning supply duct and room doors and windows are leaking. It is necessary to take measures in time.
When each chiller is installed, a layer of insulation cotton will be wrapped on the evaporator and pipes to prevent the loss of cooling capacity. If the cooling speed of the unit is slow, the enterprise should first check whether the thickness of the pipe insulation layer is not enough, or whether the insulation layer is damaged. Must remember to pack insulation cotton, and ensure enough thickness!
Check the cooling system of the chiller for air. When installing the chiller, no matter it is the inside of the unit, or the water pump or the pipeline, there can be no air, even if there is only a little air, the chiller can never operate normally. In addition, there is a film inside the pump. It is necessary to remember to tear all the water before installation. Otherwise, water can not be circulated or circulated slowly, which directly affects the operation of the chiller.
Check whether the moving parts of the refrigeration compressor are worn, or the gap increases, which leads to the decrease of gas transmission. The compressor is the heart of the water chiller. Once the compressor has problems, the water chiller will not work 100%. Therefore, the compressor regular inspection and maintenance work can not be ignored.
The poor efficiency of refrigeration compressor is also one reason. In the long-term operation of the equipment, the wear of the moving parts, the increase of the fit clearance or the lax sealing will reduce the actual gas transmission capacity and the refrigeration capacity of the compressor. Check the refrigeration compressor. If the maintenance is not good, it should be replaced in time. Air in the system can also cause this. At this time, the exhaust pressure and temperature increase, the power consumption increases, and the cooling capacity decreases.
Nanjing RICOM Refrigeration Equipment Co.,Ltd is an industry-trade integrated manufacturers for 20 years,who is engaged in the industrial temperature control technology,implements the modern quality management system ISO9001:2008 and ISO14001 environment system:2004 standard,to ensure enterprise team in technology innovation,we pay attention to customers' sense of use and satisfaction, and get the consistent recognition of the industry and customers;obtained AAA credit rating certification.In 2016, it was awarded as a contract abiding and trustworthy enterprise.In 2013,the company established the production base of chiller and mould tempering machine in Chuzhou RICOM plastic technology Co.,Ltd.