Installation And Precautions Of Chiller

Nov 13, 2020 Leave a message

  As a user of refrigeration equipment, it is very important to buy a chiller that suits your needs and is of high quality and low price. So when we buy a chiller, we should consider the next question? Of course it is installation. If you want to use this equipment, you must install and debug it before it can be put into production. The installation of equipment is a big problem for many users, because they do not understand professional knowledge, they will cause problems such as damage to the machine. Today, RICOM Refrigeration will answer the installation and precautions of industrial chillers for everyone!

  1.The site for installing the unit must be the floor, installation mat or foundation, the level of which is within 6.4mm, and can bear the operating weight of the unit.

  2.The unit should be placed in a room with a room temperature of 4.4-43.3°C, and there should be enough space around and above the unit for routine maintenance.

  3.At one end of the unit, there should be space for pipe extraction to clean the condenser tube bundle, and door openings or other suitable openings can also be used.

  4.In order to reduce noise and vibration, it is best to install vibration isolators on the pipeline.

  5.For ordinary applications, the water flow speed through the evaporator and condenser is allowed to be between 1.0-3.6m/s.

  6.Select the water pipe with the appropriate pipe diameter, the cooling system and the cold water system when the unit is running at maximum power, and connect them correctly.

  7.The design and installation of all chilled water and cooling water pipelines should be carried out according to conventional methods, and the chilled water pump should be located on the inlet pipe of the unit to ensure the positive pressure and flow in the unit. When piping, damping pipes should be installed to ensure proper flexibility, and to prevent water from the evaporator from being drained when the pump is stopped.

  8.The pipeline should have a firm support independent of the industrial chiller to avoid stress on the components of the industrial chiller. The hanger should be set up to facilitate pipe alignment.

  9.Generally speaking, correct water treatment and regular cleaning of the tube bundle can maintain its good performance. If the existing water quality conditions cannot be improved by appropriate methods, then it is necessary to consider allowing the tube bundle to have a larger fouling coefficient or specify a special Structural materials.

  10.In order to use industrial chillers economically and effectively, it is recommended to ask water treatment experts to analyze the water quality of the evaporator and condenser. Poor water quality will cause scale and affect heat transfer, or produce corrosion deposits, breed organic matter, and affect the performance of the unit. Operation and maintenance costs.

  11.Under any load conditions, the water flow should remain stable.

  12.Please install a filter at the entrance of the water pipe and clean it regularly.

  13.After the leak test is completed, all nozzles must be rust-proofed.

  14.In order to facilitate daily maintenance work, users can take some (or all) of the following measures

  (a)Pressure gauges and stop valves with plugs can be installed on the inlet and outlet pipes of cooling water and chilled water, as close as possible to industrial chillers;

  (b)Hanging rails and beams can be erected above the equipment to facilitate maintenance

  Nanjing RICOM Refrigeration Equipment Co., Ltd. is a manufacturer specializing in industrial temperature control technology for 20 years. It implements modern quality management system S09001: 2008 and environmental system IS014001: 2004 standards to ensure that the enterprise team continues to be in the technical field Innovation, focus on customer use and satisfaction, unanimously recognized by the industry and customers.