Four Manifestations Of Fluorine Deficiency in Industrial Chillers

Sep 24, 2022

Leave a message

After the industrial chiller has been used for a period of time, due to insufficient fluorine, it is necessary to check whether fluorine should be added at this time. For the chiller, what is the specific manifestation of fluorine deficiency? Today, the technical staff of the chiller manufacturer will share with you the four major manifestations of the lack of fluorine in the industrial chiller.

 

1. The compressor load becomes larger

There are many reasons for the increase of compressor load, but if the industrial chiller lacks fluorine, the compressor load will inevitably increase. If the air cooling and water cooling systems do not have poor heat dissipation, the reason for the increased compressor load is often the lack of fluorine.

 

2. The cooling capacity decreases and the cooling efficiency decreases

When the refrigeration capacity of the industrial chiller decreases, there may be many reasons for it, but the chiller lacks fluorine, especially when there is a large amount of fluorine deficiency, the refrigeration capacity of the chiller will definitely drop significantly, which will definitely affect the production efficiency of the enterprise.

 

3. High exhaust temperature

High exhaust temperature is a common phenomenon in industrial chillers. The pressure and thermometer at the exhaust end can clearly read the exhaust temperature. High exhaust temperature is not an uncommon phenomenon. Many people face the problem of high exhaust temperature. Negative response, in fact, the high exhaust temperature is the abnormal operation of the oil separator and the lack of refrigeration lubricating oil.

 

4. High energy consumption and large compressor wear

If the refrigerant is insufficient, the industrial chiller cannot meet the cooling demand, the temperature of the chilled water outlet does not meet the standard, the compressor will increase the load to meet the chilled water outlet demand, the power resource consumption is large, and the compressor wears a lot.

 

That is to say, in many cases, the observation of fluorine deficiency is not simple, especially for large-scale industrial chillers, if the refrigeration capacity and refrigeration efficiency are slightly reduced, it is difficult to detect immediately. The high probability of fluorine deficiency is due to the failure of refrigerant management and refrigerant flow pipes such as condensers, and problems with valves. , after confirming that the refrigerant does not leak and the trapping fails, start the refrigerator.

Nanjing RICOM Refrigeration Equipment Co., Ltd. is a manufacturer specializing in industrial temperature control technology for 20 years. It implements the modern quality management system S09001: 2008 and environmental system IS014001: 2004 standards to ensure that the enterprise team continues to be in the technical field. Innovation, focus on customer use and satisfaction, and have been unanimously recognized by the industry and customers.