High Temp Oil Temperature Controller

High Temp Oil Temperature Controller

High Temperature Oil Temperature Controllers provide continuous heating and precision thermal regulation up to 350 C for industrial process equipment, including injection molds, rubber presses, reactors, rollers, and heated platens.
Send Inquiry
Description

Industrial High Temperature Oil Temperature Controller

 

High Temperature Oil Temperature Controllers provide continuous heating and precision thermal regulation up to 350 C for industrial process equipment, including injection molds, rubber presses, reactors, rollers, and heated platens.

 

Technical Specifications Across Temperature Ranges

 

Specification Parameter

Standard System (Up to 200 C)

Mid-Temperature System (Up to 300 C)

High-Temperature System (Up to 350 C)

Primary Heat Transfer Fluid

Standard Mineral Thermal Oil

Synthetic Thermal Fluid

High-Temp Synthetic or Silicone Fluid

Piping and Seal Materials

Seamless Carbon Steel, NBR Seals

Stainless Steel (SS304/316), Viton Seals

Stainless Steel (SS316), Graphite, Magnetic Seals

Circulation Pump Type

Mechanical Seal Circulation Pump

High-Temp Mechanical Seal / Mag-Drive

Leak-Free Magnetic Drive Pump

Heating Control System

PID Control (Omron / Schneider)

Dual PID Control with Auto Cooling

Advanced PLC PID Control with Multi-Zone Monitoring

Standards and Compliance

CE, ISO 9001

CE, ISO 9001, PED Directive

CE, ISO 9001, PED, Optional ATEX / Explosion-Proof

 

Core System Architecture and Features

 

Component Reliability
• Electrical Systems: Built with industrial-grade components from globally recognized brands including Siemens, Schneider, and Omron.
• Circulation Pumps: Sourced from manufacturers like SPECK to handle system resistance and preserve high flow rates.
• Safety Safeguards: Features overtemperature cutoffs, low-oil sensors, pump overload protection, phase-loss monitoring, and emergency shutdown functions.

 

Engineering Recommendation
• Nitrogen Inerting Protection: For applications operating above 300 C, integrating a nitrogen blanketing system helps prevent fluid oxidation, extending thermal oil service life significantly.

 

Manufacturing, Factory Testing, and Support
• Component Verification: All heaters, pumps, valves, and control devices are audited against engineering specifications prior to assembly.
• Piping and Cabinet Assembly: Precision-welded oil circuits and structured panel wiring adhere to international electrical safety codes.
• Factory Acceptance Testing (FAT): Units undergo functional checks including electrical continuity, heating ramp rates, PID control response, pump pressure, and cooling execution.
• Documentation Package: Delivered with technical datasheets, electrical schematics, operating manuals, and spare parts references.
• Global After-Sales Support: Technical support includes remote diagnostics, standard warranty coverage, and international spare parts availability.

 

RFQ Checklist for Technical Quotation

 

To receive a detailed technical proposal, provide the following parameters:

Normal and maximum operating temperatures
Connected equipment weight, dimensions, and material type
Target heat-up time and estimated continuous heat load
Required oil flow rate and system pressure drop
Available cooling water temperature, flow rate, and inlet pressure
Local power supply parameters (Voltage, Phase, Frequency)

 

FAQ

 

Q: How do I determine whether to use oil or water as the heat transfer medium?

A: Water is typically used for operating temperatures up to 90 C (or up to 180 C in pressurized systems). Oil controllers are selected for operating temperatures above 180 C, up to 350 C, or when low system operating pressure is required at high temperatures.

Q: Why is pump pressure as important as heating capacity when selecting a controller?

A: A controller may have sufficient heating capacity, but if the pump cannot overcome the internal resistance of long piping or narrow mold channels, oil flow drops, leading to unstable heat transfer and uneven surface temperatures.

Q: How does a magnetic drive pump differ from a standard mechanical seal pump?

A: Mechanical seals rely on physical contact to prevent leaks and can wear out over time under extreme temperatures. Magnetic drive pumps eliminate direct shaft contact, offering a seal-free and leak-proof solution recommended for operation at 300 C and above.

Q: What causes thermal oil degradation, and how can it be mitigated?

A: Thermal oil degrades primarily through thermal cracking (overheating) and oxidation (exposure to air at elevated temperatures). Maintaining proper oil circulation flow, avoiding localized overheating on heating element surfaces, and using nitrogen blanketing systems significantly slow down oxidation.

Q: Can one oil temperature controller handle both heating and cooling in a single process?

A: Yes. High-temperature oil controllers feature combined heating and indirect cooling loops within the same circulation circuit. Electric heaters bring the thermal oil to the required temperature, while heat exchangers introduce cooling water to reduce fluid temperature when required by the process.

 

Hot Tags: high temp oil temperature controller, China high temp oil temperature controller manufacturers, suppliers, Centralized Mold Water Temperature Controller

Send Inquiry