An industrial air cooled water chiller is a machine that helps to cool water used in industrial processes such as manufacturing, food processing, and HVAC systems. It works by removing heat from the water and transferring it to the surrounding air through a series of coils and fans.
The cooling process is an essential part of many industries, and an air cooled chiller is a reliable and efficient method to maintain the required temperature. These chillers are designed to be durable and energy-efficient, which helps to lower overall operating costs and improve productivity.
One of the significant advantages of air-cooled chillers is that they do not require additional cooling towers or water pumps, which reduces installation costs and makes them easier to maintain. Additionally, these chillers are environmentally friendly as they use the outside air for cooling, which eliminates the need for water consumption.

Characteristics of industrial air cooled water chiller:
Industrial air cooled water chillers offer a wide range of benefits to a variety of industries. These chillers use air to dissipate heat instead of relying on water, which makes them a great option in dry environments. Here are some of the positive characteristics of industrial air cooled water chillers:
1. Efficiency: These chillers are highly efficient and offer a cost-effective solution for cooling large industrial processes. They require less maintenance and have a longer lifespan.
2. Easy Installation: As these chillers do not require a water source or cooling tower, they are much easier to install. This makes them a popular choice for retrofitting older buildings and equipment.
3. Space-saving: Air cooled chillers are much smaller in size compared to water-cooled chillers. This makes them ideal for industries that have limited space.
4. Environmentally Friendly: These chillers use the air as a cooling medium, which means they do not consume water. As a result, they are much more environmentally friendly than water-cooled chillers.
Overall, an industrial air-cooled water chiller is a vital piece of equipment that plays a significant role in many industries. Its efficiency, low cost of operation, and ease of maintenance make it an attractive option for businesses seeking to improve their operations.

Product parameters(R407C)
|
Technical Parameters of Air - Cooled Scroll Chiller(Ⅰ) |
|||||||
|
Model |
SCA-05 |
SCA-08 |
SCA-10-Ⅱ |
SCA-15-Ⅲ |
SCA-20-Ⅱ |
SCA-25-Ⅱ |
|
|
Refrigerating capacity (Kca/lKw/Rt/h) |
13583.7Kca 15.8KW 4.5Rt |
21733.2Kca 25.3KW 7.2Rt |
27167.4Kca 31.59KW 9Rt |
40751.1Kca 47.4KW 13.5Rt |
54334.8Kca 63.18KW 18Rt |
67918.5Kca 79KW 22.5Rt |
|
|
Refrigerant |
R407C |
||||||
|
compressor power(HP) |
5 |
8 |
10 |
15 |
20 |
25 |
|
|
Circulating pump power(Hp) |
0.75 |
1 |
1/1.5 |
1.5/2 |
1.5/2 |
2/3 |
|
|
Cooling fan |
Diameter(mm) |
550 |
600 |
500 |
550 |
600 |
630 |
|
Air Volume(m³/h )
|
6487 |
10820 |
2*6264 |
2*8487 |
2*10820 |
2*12220 |
|
|
Chilled drainage piping |
Pipe diameter |
1" |
1.5" |
1.5" |
2" |
2" |
2.5" |
|
Flow(m³/h) |
2.74 |
4.27 |
4.27 |
8.59 |
8.59 |
14.55 |
|
|
Supply voltage |
AC380V50HZ3PH AC440V50HZ3PH AC220V60HZ3PH |
||||||
|
Description: 1.The cooling capacity is based on evaporating temperature: 7℃, condenser temperature: 50℃, refrigerant: R407C, cooling water temperature: 32-37℃ 2.Optional refrigerant:R134A / R404A / R22 |
|||||||
|
Technical Parameters of Air - Cooled Scroll Chiller(Ⅱ) |
||||||
|
Model |
SCA-30-Ⅱ |
SCA-40 |
SCA-50 |
SCA-60 |
SCA-80 |
|
|
Refrigerating capacity (Kcal/h) |
81502.2Kca 94.77KW 27Rt |
108669.6Kca 126.36KW 36Rt |
135837Kca 158KW 45Rt |
163004.4Kca 189.5KW 53.9Rt |
217339.2Kca 252.72KW 71.9Rt |
|
|
Refrigerant |
R407C |
|||||
|
Compressor power(HP) |
30 |
40 |
50 |
60 |
80 |
|
|
Circulating pump power(Hp) |
3/4 |
40HP以上根据客户要求配置 40HP and above are configured according to customer requirements |
||||
|
Cooling fan |
Diameter(mm) |
700 |
750 |
630 |
700 |
750 |
|
Air Volume(m³/h)
|
2*15000 |
2*19000 |
3*12220 |
3*15000 |
3*19000 |
|
|
Chilled drainage piping |
Pipe diameter |
2.5" |
3" |
3" |
4" |
4" |
|
Flow(m³/h) |
14.55 |
22.06 |
22.06 |
42.2 |
42.2 |
|
|
Supply voltage |
AC380V50HZ3PH AC440V50HZ3PH AC220V60HZ3PH |
|||||
|
Description: 1.The cooling capacity is based on evaporating temperature: 7℃, condenser temperature: 50℃, refrigerant: R407C, cooling water temperature: 32-37℃ 2.Optional refrigerant:R134A / R404A / R22 |
||||||
|
Technical Parameters of Air-Cooled Screw Chiller |
||||||||
|
Model |
RC2-40A |
RC2-50A |
RC2-60A |
RC2-80A |
RC2-90A |
RC2-100A |
RC2-120A |
|
|
Refrigerating capacity (Kca/lKw/Rt/h) |
102856Kca 119.6KW 34Rt |
132870Kca 154.5KW 43.9Rt |
149124Kca 173.4KW 49.3Rt |
198230Kca 230.5KW 65.5Rt |
248110Kca 288.5KW 82Rt |
271330Kca 315.5KW 89.7Rt |
320006Kca 372.1KW 105.8Rt |
|
|
Refrigerant |
R407C |
|||||||
|
Compressor Power(Hp) |
40 |
50 |
60 |
80 |
90 |
100 |
120 |
|
|
Supply voltage |
AC380V50HZ3PH/ AC440V50HZ3PH/ AC220V60HZ3PH |
|||||||
|
Energy regulation mode |
25%-50%-75%-100% |
|||||||
|
Starting mode |
Y/▲ |
Y/▲ |
Y/▲ |
Y/▲ |
Y/▲ |
Y/▲ |
Y/▲ |
|
|
Piping of cooling water system |
Pipe diameter |
3" |
3" |
3" |
3" |
4" |
4" |
4" |
|
Description: 1.The cooling capacity is based on evaporating temperature: 7℃, condenser temperature: 50℃, refrigerant: R407C, cooling water temperature: 32-37℃ 2.Optional refrigerant:R134A / R404A / R22 |
||||||||
Pass the Iso9001 quality system certification and CE certification


Hot Tags: industrial air cooled water chiller, China, manufacturers, suppliers, wholesale, price, quotation, for sale, switch for box type chiller, industrial chiller in food processing, industrial chiller for paper mills, industrial chiller in textile industry, industrial chiller power consumption, kit of box type chiller