Water cooler industrial is a kind of water cooling equipment, is able to provide constant temperature. Constant current, constant pressure of cooling equipment, its reason is to want to put a certain amount of water injection machine of the internal water tank, through the mechanism of cold water cooling system will be water cooling, and then have the machine within the cryogenic frozen water injection pump need to cooling equipment, cold water machine the internal heat away, the high temperature cooling of the hot water back into the water again, so exchange cooling cycle, To achieve the role of cooling equipment.
How to classify industrial water chiller?
Water cooler industrial is to provide low temperature environment for the processing plant. Industrial water chiller machinery and equipment is this kind of technical professional refrigeration equipment. At this stage, there are many types of industrial chiller products.
Many processing plants or companies must meet the required temperature standards according to the water cooler industrial when producing and manufacturing, so as to realize the production and manufacturing of products. Because there are more classifications of industrial chillers, we usually classify them differently according to the different working environment of industrial chillers
1.According to the packaging type: there are two kinds of open (no box) and closed (box) water cooler industrial.
Open: usually installed outside the production workshop, is conducive to maintenance, beauty and generosity.
Closed: shell structure, convenient installation, easy to use, beautiful appearance design, in today's customer group is more popular.
2. According to the method of cold doubt, the key is water-cooled chiller and air-cooled chiller.
Water-cooled type: the industrial chiller is connected with the cooling circulating water to bring the heat from the refrigerant in the condenser.
Air-cooled type: industrial chiller is equipped with cooling fan to carry heat from the refrigerant in the condenser.
3. According to the type of evaporator of air conditioning, there are two types: submerged water cooling and shell tank type.
Submerged type: the evaporator of the air conditioner is immersed in the water storage tank to maintain refrigeration, and the centrifugal pump transmits water from the water storage tank to maintain the circulation system. (Features: first refrigeration, then water delivery)
Shell tank type: the air conditioner evaporator is made of a long barrel glass tank. The centrifugal pump transmits water from the storage tank to the air conditioner evaporator to maintain refrigeration. (Features: first conveying water, then refrigeration)
4. According to the type of refrigeration compressor: there are piston type industrial chiller, screw type industrial chiller and centrifugal industrial chiller.
Piston type: The piston type refrigeration unit is used, which has the advantages of multi-cylinder, high-speed, adjustable kinetic energy, high thermal efficiency, and suitable for a variety of refrigerants. and operating unit root test poor and other defects.
Screw type: The screw type refrigeration of imported well-known brands is used to reduce the size, with simple structure, few spare parts, light weight, very light weight, large compression ratio of stand-alone version, high cooling capacity of air conditioner, long maintenance cycle, stable operation and long service life.
Centrifugal: The centrifugal compressor is used and electricity is used as energy. The air-conditioning Freon refrigerant volatilizes and absorbs the heat of the refrigerant water in the air-conditioning evaporator to carry out refrigeration. The centrifugal impeller has a high rotational speed ratio and a large air volume. large.
5.According to the temperature can be divided into:
General industrial water chiller (5-35 degrees) and low temperature freezer (-20--35 degrees) and ultra-low temperature oil cooler (-60 degrees)
Main components of water cooler industrial
Compressor for an water cooler industrial
The compressor is the heart of the system that circulates the refrigerant. It creates the necessary differential pressure between the low and high pressure sides of the system.
Another function of the compressor is to raise the pressure and temperature of the refrigerant vapor above the ambient (ambient) temperature. This is achieved by adding work or compression heat to the refrigerant steam during the compression cycle. The compressor pumps only steam. The liquid refrigerant may damage or disable the compressor.
Condenser of water cooler industrial
The condenser is the part where the high pressure refrigerant changes from hot gas to subcooled liquid, and it rejects the heat absorbed by the refrigerant. The first few lines of the condenser will superheat and cool the high temperature gas in the exhaust pipe.
Once the condenser exhausts the heat of the superheated steam and reaches saturation temperature, these gases will reach 100% saturated vapor, at which point the refrigerant will begin to change its state from saturated vapor to liquid. After the refrigerant is cooled to 100% liquid, the refrigerant liquid will begin to subcool at the end of the condenser.

Evaporator for water cooler industrial
The evaporator is the part where the low pressure low temperature refrigerant absorbs heat from the cooled medium (water/glycol liquid).
The refrigerant absorbs a large amount of heat from the cooled medium, causing the state of the refrigerant to change from cryogenic liquid to superheated vapor. The temperature difference between the cryogenic refrigerant and the medium being cooled is the underlying driving force for heat transfer to occur.

Expansion valve for water cooler industrial
It is a throttling and depressurizing component, which reduces the condensing pressure of the refrigerant to the evaporating pressure, so it is an indispensable component in the refrigeration system. Four parts.

We know that no matter how good and stable equipment is, it needs the patience and care of users to ensure a long service life and bring more stable income to the company. The industrial chiller unit is affected by different units or different water quality. Not the same. It is very necessary to conduct a comprehensive maintenance of the chiller every year. The following are the items that should be performed in the maintenance:
Maintenance of water cooler industrial
Clean the condenser
The impurities in the water quality will be attached to the condenser due to long-term use, and the heat dissipation effect will be affected if the time is too long.
Cleaning the cooling circulating water system
The chiller must be equipped with a cooling water tower and a water pump to provide cooling circulating water. Algae and impurities are prone to appear in the water tower. Because it needs to be cleaned regularly, it is also necessary to install a filter at the water source.
Check the refrigeration oil of the compressor
The refrigeration oil mainly plays the functions of lubrication, sealing, cooling and energy regulation. If there is a shortage, it needs to be replenished and replaced in time.
Check whether the fasteners of the unit are loose
Properly tighten each fastener to eliminate vibration and prevent leakage.
Check the electrical system of the unit
Check the circuit system of the unit, test whether the power supply is normal, lack of phase, whether the operating current is temperature, and whether the control circuit device is loose and aging.
Check the refrigeration compressor of the chiller
Check the refrigeration compressor of the chiller, and do an insulation test for the motor coil of the compressor.
Check filter drier, expansion valve
Check the filter drier and whether the expansion valve is normally blocked or not, and need to be replaced if necessary.
Check refrigerant quantity
Check refrigerant quantity, if lack, should be replenished in time.
Calibrate high and low pressure switches
Calibration of high and low pressure switches, temperature sensors.
Description(R407C)
Technical Parameters of Water Cooled Scroll Chiller(Ⅰ) | |||||||
Model | SCW-05 | SCW-08 | SCW-10-Ⅱ | SCW-15-Ⅲ | SCW-20-Ⅱ | SCW-25-Ⅱ | |
Refrigerating capacity (Kcal/lKw/Rt/h) | 15093Kcal 17.55KW 4.99RT | 24148Kcal 28.08KW 7.98RT | 30186Kcal 35.1KW 9.98RT | 45279Kcal 52.65KW 14.97RT | 60372Kcal 70.2KW 19.96RT | 75465Kcal 87.75KW 24.95RT | |
Refrigerant | R407C | ||||||
compressor power(Hp) | 5 | 8 | 10 | 15 | 20 | 25 | |
Circulating pump power(Hp) | 0.75 | 1 | 1/1.5 | 1.5/2 | 1.5/2 | 2/3 | |
Piping of cooling water system | pipe diameter | 1" | 1.5" | 1.5" | 2" | 2" | 2.5" |
Flow(m³/h) | 3.4 | 5.5 | 6.85 | 9.3 | 12.7 | 15.1 | |
Chilled drainage piping | pipe diameter | 1" | 1.5" | 1.5" | 2" | 2" | 2.5" |
Flow(m³/h) | 2.74 | 4.27 | 4.27 | 8.59 | 8.59 | 14.55 | |
supply voltage | AC380V50HZ3PH AC440V50HZ3PH AC220V60HZ3PH | ||||||
Description: 1.The cooling capacity is based on evaporating temperature: 7℃, condenser temperature: 40℃, refrigerant: R407C, cooling water temperature: 32-37℃ 2.Optional refrigerant:R134A / R404A / R22 | |||||||
Technical Parameters of Water Cooled Scroll Chiller(Ⅱ) | ||||||
Model | SCW-30-Ⅱ | SCW-40 | SCW-50 | SCW-60 | SCW-80 | |
Refrigerating capacity (Kcal/lKw/Rt/h) | 90558Kcal 105.3KW 29.94RT | 120744Kcal 140.4KW 39.92RT | 150930Kcal 175.5KW 49.9RT | 181116Kcal 210.6KW 59.88RT | 241488Kcal 280.8KW 79.84RT | |
Refrigerant | R407C | |||||
compressor power(Hp) | 30 | 40 | 50 | 60 | 80 | |
Circulating pump power(Hp) | 3/4 | 40HP and above are configured according to customer requirements | ||||
Piping of cooling water system | pipe diameter | 2.5" | 3" | 3" | 4" | 4" |
Flow(m³/h)
| 18.5 | 24.5 | 30.2 | 36.2 | 48.2 | |
Chilled drainage piping | pipe diameter | 2.5" | 3" | 3" | 4" | 4" |
Flow(m³/h) | 14.55 | 22.06 | 22.06 | 42.2 | 42.2 | |
supply voltage | AC380V50HZ3PH AC440V50HZ3PH AC220V60HZ3PH | |||||
Description: 1.The cooling capacity is based on evaporating temperature: 7℃, condenser temperature: 40℃, refrigerant: R407C, cooling water temperature: 32-37℃ 2.Optional refrigerant:R134A / R404A / R22 | ||||||
Technical Parameters of Air - Cooled Scroll Chiller(Ⅰ) | |||||||
Model | SCA-05 | SCA-08 | SCA-10-Ⅱ | SCA-15-Ⅲ | SCA-20-Ⅱ | SCA-25-Ⅱ | |
Refrigerating capacity (Kca/lKw/Rt/h) | 13583.7Kca 15.8KW 4.5Rt | 21733.2Kca 25.3KW 7.2Rt | 27167.4Kca 31.59KW 9Rt | 40751.1Kca 47.4KW 13.5Rt | 54334.8Kca 63.18KW 18Rt | 67918.5Kca 79KW 22.5Rt | |
Refrigerant | R407C | ||||||
compressor power(HP) | 5 | 8 | 10 | 15 | 20 | 25 | |
Circulating pump power(Hp) | 0.75 | 1 | 1/1.5 | 1.5/2 | 1.5/2 | 2/3 | |
Cooling fan | Diameter(mm) | 550 | 600 | 500 | 550 | 600 | 630 |
Air Volume(m³/h )
| 6487 | 10820 | 2*6264 | 2*8487 | 2*10820 | 2*12220 | |
Chilled drainage piping | Pipe diameter | 1" | 1.5" | 1.5" | 2" | 2" | 2.5" |
Flow(m³/h) | 2.74 | 4.27 | 4.27 | 8.59 | 8.59 | 14.55 | |
Supply voltage | AC380V50HZ3PH AC440V50HZ3PH AC220V60HZ3PH | ||||||
Description: 1.The cooling capacity is based on evaporating temperature: 7℃, condenser temperature: 50℃, refrigerant: R407C, cooling water temperature: 32-37℃ 2.Optional refrigerant:R134A / R404A / R22 | |||||||
Technical Parameters of Air - Cooled Scroll Chiller(Ⅱ) | ||||||
Model | SCA-30-Ⅱ | SCA-40 | SCA-50 | SCA-60 | SCA-80 | |
Refrigerating capacity (Kcal/h) | 81502.2Kca 94.77KW 27Rt | 108669.6Kca 126.36KW 36Rt | 135837Kca 158KW 45Rt | 163004.4Kca 189.5KW 53.9Rt | 217339.2Kca 252.72KW 71.9Rt | |
Refrigerant | R407C | |||||
Compressor power(HP) | 30 | 40 | 50 | 60 | 80 | |
Circulating pump power(Hp) | 3/4 | 40HP以上根据客户要求配置 40HP and above are configured according to customer requirements | ||||
Cooling fan | Diameter(mm) | 700 | 750 | 630 | 700 | 750 |
Air Volume(m³/h)
| 2*15000 | 2*19000 | 3*12220 | 3*15000 | 3*19000 | |
Chilled drainage piping | Pipe diameter | 2.5" | 3" | 3" | 4" | 4" |
Flow(m³/h) | 14.55 | 22.06 | 22.06 | 42.2 | 42.2 | |
Supply voltage | AC380V50HZ3PH AC440V50HZ3PH AC220V60HZ3PH | |||||
Description: 1.The cooling capacity is based on evaporating temperature: 7℃, condenser temperature: 50℃, refrigerant: R407C, cooling water temperature: 32-37℃ 2.Optional refrigerant:R134A / R404A / R22 | ||||||
Technical Parameters of Water - Cooled Screw Chiller(Ⅰ) | |||||||
Model | RC2-40W | RC2-50W | RC2-60W | RC2-80W | RC2-90W | RC2-100W | |
Refrigerating capacity (Kca/lKw/Rt/h) | 119282Kca 138.7KW 39.4Rt | 154026Kca 179.1KW 50.9Rt | 172946Kca 201.1KW 57.2Rt | 229878Kca 267.3KW 76Rt | 287670Kca 334.5KW 95.1Rt | 314502Kca 365.7KW 104Rt | |
Refrigerant | R407C | ||||||
Compressor Power(Hp) | 40 | 50 | 60 | 80 | 90 | 100 | |
Supply voltage | AC380V50HZ3PH AC440V50HZ3PH AC220V60HZ3PH | ||||||
Energy regulation mode | 25%-50%-75%-100% | ||||||
Starting mode | Y/▲ | Y/▲ | Y/▲ | Y/▲ | Y/▲ | Y/▲ | |
Piping of cooling water system | Pipe diameter | 3" | 3" | 3" | 3" | 4" | 4" |
Chilled drainage piping | Pipe diameter | 3" | 3" | 3" | 3" | 4" | 4" |
Description: 1.The cooling capacity is based on evaporating temperature: 7℃, condenser temperature: 40℃, refrigerant: R407C, cooling water temperature: 32-37℃ 2.Optional refrigerant:R134A / R404A / R22 | |||||||
Technical Parameters of Water - Cooled Screw Chiller(Ⅱ) | |||||||
Model | RC2-110W | RC2-120W | RC2-140W | RC2-150W | RC2-160W | RC2-180W | |
Refrigerating capacity (Kcal/h) | 343742Kca 399.7KW 113.6Rt | 371004Kca 431.4KW 122.7Rt | 439030Kca 510.5KW 145.2Rt | 463540Kca 539KW 153.3Rt | 512818Kca 596.3KW 169.5Rt | 571470Kca 664.5KW 188.9Rt | |
Refrigerant | R407C | ||||||
Compressor Power(Hp) | 110 | 120 | 140 | 150 | 160 | 180 | |
Supply voltage | AC380V50HZ3PH AC440V50HZ3PH AC220V60HZ3PH | ||||||
Energy regulation mode | 25%-50%-75%-100% | ||||||
Starting mode | Y/▲ | Y/▲ | Y/▲ | Y/▲ | Y/▲ | Y/▲ | |
Piping of cooling water system | Pipe diameter | 4" | 4" | 5" | 5" | 5" | 5" |
Chilled drainage piping | Pipe diameter | 4" | 4" | 5" | 5" | 5" | 5" |
Description: 1.The cooling capacity is based on evaporating temperature: 7℃, condenser temperature: 40℃, refrigerant: RR407C, cooling water temperature: 32-37℃ 2.Optional refrigerant:R134A / R404A / R22 | |||||||
Technical Parameters of Water - Cooled Screw Chiller(Ⅲ) | |||||||
Model | RC2-200W | RC2-220W | RC2-240W | RC2-280W | RC2-300W | RC2-320W | |
Refrigerating capacity (Kca/lKw/Rt/h) | 664952Kca 773.2KW 219.8Rt | 730312Kca 849.2KW 241.5Rt | 742008Kca 862.8KW 245.3Rt | 878060Kca 1021KW 290.3Rt | 927080Kca 1078KW 306.5Rt | 1025636Kca 1192.6KW 339.1Rt | |
Refrigerant | R407C | ||||||
Compressor Power(Hp) | 200 | 220 | 240 | 280 | 300 | 320 | |
Supply voltage | AC380V50HZ3PH/ AC440V50HZ3PH/ AC220V60HZ3PH | ||||||
Energy regulation mode | 25%-50%-75%-100% | ||||||
Starting mode | Y/▲ | Y/▲ | Y/▲ | Y/▲ | Y/▲ | Y/▲ | |
Piping of cooling water system | Pipe diameter | 5" | 5" | 5" | 6" | 6" | 6" |
Chilled drainage piping | Pipe diameter | 5" | 5" | 5" | 6" | 6" | 6" |
Description: 1.The cooling capacity is based on evaporating temperature: 7℃, condenser temperature: 40℃, refrigerant: R407C, cooling water temperature: 32-37℃ 2.Optional refrigerant:R134A / R404A / R22 | |||||||
Technical Parameters of Water - Cooled Screw Chiller(Ⅳ) | ||||||
Model | RC2-340W | RC2-360W | RC2-400W | RC2-460W | RC2-560W | |
Refrigerating capacity (Kca/lKw/Rt/h) | 1092888Kca 1270.8KW 361.3Rt | 1142940Kca 1329KW 377.9Rt | 1329904Kca 1546.4KW 439.7Rt | 1460624Kca 1698.4KW 482.9Rt | 1756120Kca 2042KW 580.6Rt | |
Refrigerant | R407C | |||||
Compressor Power(Hp) | 340 | 360 | 400 | 460 | 560 | |
Supply voltage | AC380V50HZ3PH/ AC440V50HZ3PH/ AC220V60HZ3PH | |||||
Energy regulation mode | 25%-50%-75%-100% | |||||
Starting mode | Y/▲ | Y/▲ | Y/▲ | Y/▲ | Y/▲ | |
Piping of cooling water system | Pipe diameter | 6" | 8" | 8" | 8" | 8" |
Chilled drainage piping | Pipe diameter | 6" | 8" | 8" | 8" | 8" |
Description: 1.The cooling capacity is based on evaporating temperature: 7℃, condenser temperature: 40℃, refrigerant: R407C, cooling water temperature: 32-37℃ 2.Optional refrigerant:R134A / R404A / R22 | ||||||
Technical Parameters of Air-Cooled Screw Chiller | ||||||||
Model | RC2-40A | RC2-50A | RC2-60A | RC2-80A | RC2-90A | RC2-100A | RC2-120A | |
Refrigerating capacity (Kca/lKw/Rt/h) | 102856Kca 119.6KW 34Rt | 132870Kca 154.5KW 43.9Rt | 149124Kca 173.4KW 49.3Rt | 198230Kca 230.5KW 65.5Rt | 248110Kca 288.5KW 82Rt | 271330Kca 315.5KW 89.7Rt | 320006Kca 372.1KW 105.8Rt | |
Refrigerant | R407C | |||||||
Compressor Power(Hp) | 40 | 50 | 60 | 80 | 90 | 100 | 120 | |
Supply voltage | AC380V50HZ3PH/ AC440V50HZ3PH/ AC220V60HZ3PH | |||||||
Energy regulation mode | 25%-50%-75%-100% | |||||||
Starting mode | Y/▲ | Y/▲ | Y/▲ | Y/▲ | Y/▲ | Y/▲ | Y/▲ | |
Piping of cooling water system | Pipe diameter | 3" | 3" | 3" | 3" | 4" | 4" | 4" |
Description: 1.The cooling capacity is based on evaporating temperature: 7℃, condenser temperature: 50℃, refrigerant: R407C, cooling water temperature: 32-37℃ 2.Optional refrigerant:R134A / R404A / R22 | ||||||||
Technological Process


Multiple Protection

Used in case sites in various industries

High Quality
Pass the Iso9001 quality system certification and CE certification


Hot Tags: water cooler industrial, China, manufacturers, suppliers, wholesale, price, quotation, for sale, industrial chiller for dairy farms, industrial chiller for greenhouses, industrial chiller cooling capacity, industrial chiller expansion valve, industrial chiller in pharmaceutical industry, industrial chiller rental