Product Description
The cold and hot chiller is divided into two parts: the heating part and the cooling part. Precise temperature control, widely used in injection molding, chemical industry, rubber extrusion, reaction kettle, blow molding and other industries.
The cold and hot all-in-one chiller can realize the mutual switch to speed up the production schedule and reduce energy consumption, improve the forming efficiency of products, restrain the defects of products and reduce the occurrence of defective products.Computer touch control, automatic calculation, multi - point temperature control units can be customized.
It can automatically and accurately control the temperature, can quickly reach the set temperature, set value and actual value display respectively. Isolated electrical control box, extend the service life of electrical appliances, pipeline explosion-proof device, built-in safety protection low noise, high temperature resistance, corrosion and rust, unique heating design, power saving and durable suitable for different temperature control places.
Nanjing RICOM Refrigeration Equipment Co., Ltd. water-cooled cold and hot chiller is divided into two types: screw and scroll.

Product Principle

Product Characteristics
Heating Part
1. Computer touch control, separate electrical control, easy to understand operation.
2. The temperature control table is controlled by microcomputer with two sets of P.I.D., and it is accurate and reliable, saving more than 35% of power.
3. Perfect safety protection and fault indication system, pipeline explosion-proof device.
4. Imported advanced components, RS485 communication function, imported microcomputer or PLC control.
5. Mould oil return, full negative pressure operation and other functions, starting automatic exhaust and forced cooling functions.
6. Stainless steel integrated molding, pipe resistance small, uniform heating, heating power switching function.
Refrigeration Part
1. Imported compressor, low noise, high energy efficiency.
2. High-efficiency evaporator and condenser can save more than 30%.
3. Imported advanced components, long service life.
4. Imported high-precision dual-channel digital display power-saving temperature control meter.
5. Two sets of compressors, which can be used individually or together (above C-10).
6. Perfect safety protection and fault indication system.
7. Microcomputer touch control, easy to understand operation (optional).
8. Copper pipes are welded without oxygen.


Product Process
Nanjing RICOM Refrigeration Equipment Co., Ltd. adheres to the spirit of craftsmanship and creates high-quality products.


Product Parameters
Technical parameters of water - cooled screw cold - hot chiller | ||||||||
Model | RC2-40WLR | RC2-50WLR | RC2-60WLR | RC2-80WLR | RC2-90WLR | RC2-100WLR | RC2-110WLR | |
Refrigerating capacity (Kcal/h) | 122980/143/40.7 | 161422/187.7/53.4 | 173376/201.6/57.4 | 231942/269.7/76.7 | 288788/335.8/95.5 | 321554/373.9/106.4 | 346322/402.7/114.5 | |
Refrigerant | R22/R134A/ | R22/R134A/ | R22/R134A/ | R22/R134A/ | R22/R134A/ | R22/R134A/ | R22/R134A/ | |
Compressor Power (Hp) | 40 | 50 | 60 | 80 | 90 | 100 | 110 | |
Heating power (Kca/lKw/Rt/h) | 149640/174/49.5 | 194360/226.7/64.5 | 210356/244.6/69.6 | 280274/325.9/92.7 | 347096/403.6/114.8 | 385108/447.8/127.3 | 415294/482.9/137.3 | |
Supply voltage | AC380V50HZ3PH/ | AC380V50HZ3PH/ | AC380V50HZ3PH/ | AC380V50HZ3PH/ | AC380V50HZ3PH/ | AC380V50HZ3PH/ | AC380V50HZ3PH/ | |
Energy regulation mode | 25%-50%-75%-100% | 25%-50%-75%-100% | 25%-50%-75%-100% | 25%-50%-75%-100% | 25%-50%-75%-100% | 25%-50%-75%-100% | 25%-50%-75%-100% | |
Starting mode | Y/▲ | Y/▲ | Y/▲ | Y/▲ | Y/▲ | Y/▲ | Y/▲ | |
Piping of cooling water system | Pipe diameter | 3" | 3" | 3" | 3" | 4" | 4" | 4" |
Chilled drainage piping | Pipe diameter | 3" | 3" | 3" | 3" | 4" | 4" | 4" |
Refrigerating capacity is based on evaporation temperature of 7℃, condenser temperature of 40℃, refrigerant: R22, and cooling water temperature of 32-37℃ | ||||||||
Model | RC2-120WLR | RC2-140WLR | RC2-150WLR | RC2-160WLR | RC2-240WLR | RC2-280WLR | RC2-300WLR | |
Refrigerating capacity (Kcal/h) | 376594/437.9/124.5 | 457348/531.8/151.2 | 477988/555.8/158 | 528642/614.7/174.8 | 811066/943.1/268.2 | 914696/1063.6/302.4 | 955976/1111.6/316 | |
Refrigerant | R22/R134A/ | R22/R134A/ | R22/R134A/ | R22/R134A/ | R22/R134A/ | R22/R134A/ | R22/R134A/ | |
Compressor Power (Hp) | 103200/120/34.1 | 120400/140/39.9 | 129000/150/42.6 | 137600/160/45.5 | 206400/240/68.2 | 240800/280/79.6 | 258000/300/85.3 | |
Heating power (Kca/lKw/Rt/h) | 526.2 | 637.5 | 664 | 736.5 | 1052.4 | 1275 | 1431.9 | |
Supply voltage | AC380V50HZ3PH/ | AC380V50HZ3PH/ | AC380V50HZ3PH/ | AC380V50HZ3PH/ | AC380V50HZ3PH/ | AC380V50HZ3PH/ | AC380V50HZ3PH/ | |
Energy regulation mode | 25%-50%-75%-100% | 25%-50%-75%-100% | 25%-50%-75%-100% | 25%-50%-75%-100% | 25%-50%-75%-100% | 25%-50%-75%-100% | 25%-50%-75%-100% | |
Starting mode | Y/▲ | Y/▲ | Y/▲ | Y/▲ | Y/▲ | Y/▲ | Y/▲ | |
Piping of cooling water system | Pipe diameter | 4" | 5" | 5" | 5" | 5" | 6" | 6" |
Chilled drainage piping | Pipe diameter | 4" | 5" | 5" | 5" | 5" | 6" | 6" |
Refrigerating capacity is based on evaporation temperature of 7℃, condenser temperature of 40℃, refrigerant: R22, and cooling water temperature of 32-37℃ | ||||||||
Technical parameters of water - cooled scroll cold - hot chiller | |||||||
Model | SCW-05LR | SCW-08LR | SCW-10LR-Ⅱ | SCW-15LR-Ⅲ | SCW-20LR-Ⅱ | SCW-25LR-Ⅱ | |
Refrigerating capacity (Kcal/h) | 15093/17.55/5 | 24148/28.08/8 | 30186/35.1/10 | 45279/52.65/15 | 60372/70.2/20 | 75465/87.75/25 | |
Refrigerant | R22/R134A/ | R22/R134A/ | R22/R134A/ | R22/R134A/ | R22/R134A/ | R22/R134A/ | |
Compressor power (Hp) | 5 | 8 | 10 | 15 | 20 | 25 | |
Heating power (Kca/lKw/Rt/h) | 18111.6/21.06/6 | 28982/33.7/9.6 | 36223.2/42.12/12 | 54334.8/63.18/18 | 72446.4/84.24/24 | 90558/105.3/30 | |
Circulating pump power (Hp) | 1 | 2 | 2 | 3 | 3 | 4 | |
Piping of cooling water system | Pipe diameter | 1" | 1.5" | 1.5" | 2" | 2" | 2.5" |
Flow (m³/h) | 3.4 | 5.5 | 6.85 | 9.3 | 12.7 | 15.1 | |
Chilled drainage piping | Pipe diameter | 1" | 1.5" | 1.5" | 2" | 2" | 2.5" |
Flow (m³/h) | 2.74 | 4.27 | 4.27 | 8.59 | 8.59 | 14.55 | |
supply voltage | AC380V50HZ3PH | AC380V50HZ3PH | AC380V50HZ3PH | AC380V50HZ3PH | AC380V50HZ3PH | AC380V50HZ3PH | |
Refrigerating capacity is based on evaporation temperature of 7℃, condenser temperature of 40℃, refrigerant: R22, and cooling water temperature of 32-37℃ | |||||||
Model | SCW-30LR-Ⅱ | SCW-40LR | SCW-50LR | SCW-60LR | SCW-80LR | |
Refrigerating capacity (Kcal/h) | 90558/105.3/29.9 | 120744/140.4/40 | 150930/175.5/50 | 181116/210.6/60 | 241488/280.8/80 | |
Refrigerant | R22/R134A/ | R22/R134A/ | R22/R134A/ | R22/R134A/ | R22/R134A/ | |
Compressor power (Hp) | 30 | 40 | 50 | 60 | 80 | |
Heating power (Kca/lKw/Rt/h) | 108669.6/126.36/35.9 | 144892.8/168.48/47.9 | 181116/210.6/59.9 | 217339.2/252.72/71.9 | 289785.6/336.96/95.8 | |
Circulating pump power (Hp) | 4 | 40HP and above are configured according to customer requirements | 40HP and above are configured according to customer requirements | 40HP and above are configured according to customer requirements | 40HP and above are configured according to customer requirements | |
Piping of cooling water system | Pipe diameter | 2.5" | 3" | 3" | 4" | 4" |
Flow (m³/h) | 18.5 | 24.5 | 30.2 | 36.2 | 48.2 | |
Chilled drainage piping | Pipe diameter | 2.5" | 3" | 3" | 4" | 4" |
Flow (m³/h) | 14.55 | 22.06 | 22.06 | 42.2 | 42.2 | |
Supply voltage | AC380V50HZ3PH | AC380V50HZ3PH | AC380V50HZ3PH | AC380V50HZ3PH | AC380V50HZ3PH | |
Refrigerating capacity is based on evaporation temperature of 7℃, condenser temperature of 40℃, refrigerant: R22, and cooling water temperature of 32-37℃ | ||||||
Customer Case
Cold and hot all-in-one chiller is widely used in injection molding, chemical, rubber extrusion, reaction kettle, blow molding and other industries.
My company has served many industries, has a wealth of industry application experience.

FAQ
Common problems when buying products
Q: How long has your company been established?
A: Our company was founded in 2014, but most of our engineers have been in the industry for over 15 years, and our boss has been in the industry for over 20 years.
Q: Is your company a trading company?
A: Our company is a trading company, but we have our own factory.
Q: What are your terms of payment?
A: T/T pays 30% in advance and 100% before delivery.
Q: How long is your delivery time?
A: 25-30 working days for standard products and 45 working days for non-standard customization
Q: How long is the warranty?
A: If the parts are broken or damaged, within 18 months from the date of leaving the factory.
These parts are provided free of charge by our company (except for wearing parts due to quality problems).
Hot Tags: water cooled screw or scroll cold and hot chiller, China water cooled screw or scroll cold and hot chiller manufacturers, suppliers, upkeep service for box type chiller, rohs compliant box type chiller, used box type chiller, wholesale box type chiller, operation manual for box type chiller, detector for box type chiller